We earn a commission if you buy through links on this page. It does not change the price you pay or what we write. Details

Wattshelf

Goal Zero Yeti 1500X

Data last changed 2026-11-16. We have not tested this unit; every number comes from the maker's pages linked below. 13 of 16 fields are published by the maker.

Where to buy

Check price at Goal Zero

We earn a commission if you buy through links on this page. It does not change the price you pay or what we write. Details

Specifications

Every row links to the maker's page it came from and shows the date we checked it. "Not published by the maker" means we looked and the page does not say; it does not mean zero.
Spec Value Source Checked
Nominal capacity 1516 Wh source
"1516Wh (10.8V, 140.4Ah)".
Usable capacity (maker's figure) Not published by the maker none: nothing to cite
Not stated on the pages read.
AC output, continuous 2000 W source
"2x AC: 2000W, 3500W Surge (120VAC 60Hz, 16.5A), Pure Sine Wave".
AC output, surge 3500 W source
AC outlets 2 outlets (120V AC) source
Battery chemistry Li-ion NMC source
"Cell chemistry: Li-ion NMC".
Rated charge cycles 500 cycles to 80% capacity source
"500 Cycles to 80% capacity (1C, 25C)".
Max solar input 600 W source
"Solar Charging (600W Actual Input Max)"; high power port 14-50V up to 50A (600W max).
Solar input voltage 14-50 V DC source
Recharge time from AC 100% in 14 h (included 120W supply; 3 h with optional 600W supply) sources disagree source
"14 hours" with included 120W supply; 7 h with 230W; 3 h with 600W.
Weight 20.7 kg source
"45.64 lbs (20.7kg)".
Dimensions 387.4 x 259.8 x 263.4 mm source
"15.25 x 10.23 x 10.37 in (38.74 x 25.98 x 26.34 cm)" - orig. page typo "1 5.25".
Warranty 2 years source
"Warranty: 2 years" in spec block; another block on the same page says "UP TO 2 YEAR WARRANTY".
Expandable capacity No (Chainable: No) sources disagree source
The page says both "Chainable: No" and, in the header spec, "Chainable: With Yeti Link and Tank Expansion batteries" - see discrepancies.
UPS switch-over time Not published by the maker none: nothing to cite
Not stated.

Where the maker's own pages disagree

We do not pick a winner silently. The table above shows the value we used; these are the conflicting statements found on the maker's pages.

Price

We show no price here. Store prices change daily and we have no price feed yet, and the maker does not state a list price (MSRP) on the pages we read. The button above goes to the maker's page, which shows today's price.

Who it is NOT for

What it can run

Usable capacity used: 1288.6 Wh calculated by us from the nominal 1516 Wh x 0.85 . The maker publishes no usable figure, so we assume 85% of nominal is usable. That factor is our assumption, not a measurement of this unit.

Runtime = usable Wh / watts the appliance draws, as constant draw. Continuous check against 2000 W; start-up check against 3500 W surge . Appliance figures are from the appliance database, which shows each source; where sources disagree we show the range, not an average. 13 appliances have no usable figure yet and are left out. Runtimes calculated by us from the usable Wh above and each appliance's watts .

Kitchen

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
Air fryer (generic) 1500 W Yes No start-up figure in the source 52 min
Blender (generic) 500 W Yes Yes (needs 1200 W at start) 2 h 35 min
Chest freezer (ENERGY STAR avg, n small) 24.3 W (24 h average) Yes No start-up figure in the source 53 h 2 min
Coffee maker (drip) 800 W (sources range 750 to 1200 W) sources disagree Yes No start-up figure in the source 1 h 4 min to 1 h 43 min
Compact freezer (ENERGY STAR avg) 27.9 W (24 h average) Yes No start-up figure in the source 46 h 11 min
Compact refrigerator / dorm fridge (ENERGY STAR avg) 28.1 W (24 h average) Yes No start-up figure in the source 45 h 51 min
Dishwasher 1200 W Yes Yes (needs 2700 W at start) 1 h 4 min
Electric burner (single hot plate) 1300 W (sources range 1300 to 2400 W) Only at the low end No (needs 4300 W at start) (low-confidence figure in its source) 32 min to 59 min (only if it draws within the continuous rating)
Electric grill 1500 W Yes No (needs 4500 W at start) (low-confidence figure in its source) 52 min
Electric range with oven 12200 W No No start-up figure in the source not supported (above the continuous rating)
Electric skillet 1000 W Yes Yes (needs 3000 W at start) (low-confidence figure in its source) 1 h 17 min
Electric stove (generic, Champion) 2000 W Yes No start-up figure in the source 39 min
High-power blender (Vitamix 5200) up to 1380 W (a rating, not a measured draw) Yes No start-up figure in the source at least 56 min
Microwave oven 800 W (sources range 600 to 1500 W) Yes Yes (needs 2800 W at start) (low-confidence figure in its source) 52 min to 2 h 9 min
Multi-cooker / pressure cooker (Instant Pot Duo 6 qt) 1000 W Yes No start-up figure in the source 1 h 17 min
Refrigerator, bottom freezer (ENERGY STAR avg) 62.9 W (24 h average) Yes No start-up figure in the source 20 h 29 min
Refrigerator, freezerless/single door (ENERGY STAR avg) 32.9 W (24 h average) Yes No start-up figure in the source 39 h 10 min
Refrigerator, side-by-side (ENERGY STAR avg) 71.2 W (24 h average) Yes No start-up figure in the source 18 h 6 min
Refrigerator, top freezer (ENERGY STAR avg) 41.4 W (24 h average) Yes No start-up figure in the source 31 h 8 min
Refrigerator/freezer (full size, generic) 700 W (sources range 400 to 750 W) sources disagree Yes Yes (needs 2900 W at start) 1 h 43 min to 3 h 13 min
Toaster 900 W (sources range 850 to 1100 W) sources disagree Yes No start-up figure in the source 1 h 10 min to 1 h 31 min
Toaster oven 1200 W Yes No start-up figure in the source 1 h 4 min
Upright freezer (ENERGY STAR avg) 50 W (24 h average) Yes No start-up figure in the source 25 h 46 min

Home

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
Ceiling fan 36-45 in (ENERGY STAR) 22 W (sources range 3 to 35.3 W) Yes No start-up figure in the source 36 h 30 min to 429 h 32 min
Ceiling fan 48-52 in (ENERGY STAR) 28.6 W (sources range 3.3 to 47.2 W) Yes No start-up figure in the source 27 h 18 min to 390 h 29 min
Ceiling fan 54-60 in (ENERGY STAR) 32.2 W (sources range 3.2 to 41.4 W) Yes No start-up figure in the source 31 h 8 min to 402 h 41 min
Central air conditioner 3 ton 6000 W No No (needs 18000 W at start) not supported (above the continuous rating)
Dehumidifier ~25 pints/day (ENERGY STAR derived) 262 W (sources range 220 to 289 W) Yes No start-up figure in the source 4 h 28 min to 5 h 51 min
Dehumidifier ~35 pints/day (ENERGY STAR derived) 347 W (sources range 294 to 400 W) Yes No start-up figure in the source 3 h 13 min to 4 h 23 min
Dehumidifier ~50 pints/day (ENERGY STAR derived) 488 W (sources range 396 to 491 W) Yes No start-up figure in the source 2 h 37 min to 3 h 15 min
Desk lamp 40 W Yes Yes (needs 740 W at start) (low-confidence figure in its source) 32 h 13 min
Electric heat pump 6000 W No No (needs 18000 W at start) not supported (above the continuous rating)
Electric water heater (50 gal) 4500 W (sources range 4500 to 5000 W) No No start-up figure in the source not supported (above the continuous rating)
Furnace blower fan 1/2 HP 600 W Yes Yes (needs 1800 W at start) 2 h 9 min
Furnace blower fan 1/3 HP 450 W (sources range 450 to 700 W) sources disagree Yes Yes (needs 1350 W at start) 1 h 50 min to 2 h 52 min
Furnace blower fan 1/4 HP 400 W Yes Yes (needs 1200 W at start) 3 h 13 min
Garage door opener 1/2 HP 1050 W Yes Yes (needs 3150 W at start) 1 h 14 min
Garage door opener 1/3 HP 750 W Yes Yes (needs 2250 W at start) 1 h 43 min
Hair dryer 600 to 1400 W Yes No start-up figure in the source 55 min to 2 h 9 min
Home security system 200 W Yes No start-up figure in the source 6 h 27 min
Household lights (per fixture, generic) 40 to 150 W Yes No start-up figure in the source 8 h 35 min to 32 h 13 min
Humidifier 177 W Yes No start-up figure in the source 7 h 17 min
Incandescent bulb 60 W 60 W Yes No start-up figure in the source 21 h 29 min
Incandescent bulb 75 W 75 W Yes No start-up figure in the source 17 h 11 min
LED bulb 15 W 15 W Yes No start-up figure in the source 85 h 54 min
Portable heater with fan 500 to 1500 W Yes No start-up figure in the source 52 min to 2 h 35 min
Room air purifier (ENERGY STAR avg) 17.4 W (24 h average) Yes No start-up figure in the source 74 h 3 min
Space heater (electric) 1500 W (sources range 500 to 1500 W) sources disagree Yes No start-up figure in the source 52 min to 2 h 35 min
Starlink Standard kit (dish + router) 50 to 75 W Yes No start-up figure in the source 17 h 11 min to 25 h 46 min
Sump pump 1/2 HP 1050 W (sources range 1000 to 1050 W) sources disagree Yes Yes (needs 3250 W at start) 1 h 14 min to 1 h 17 min
Sump pump 1/3 HP 800 W Yes Yes (needs 2100 W at start) 1 h 37 min
Vacuum cleaner 800 W Yes No start-up figure in the source 1 h 37 min
Well pump 1/2 HP 1000 W Yes Yes (needs 3000 W at start) 1 h 17 min
Well pump 1/3 HP 1000 W (sources range 750 to 1000 W) sources disagree Yes Yes (needs 3000 W at start) 1 h 17 min to 1 h 43 min
Well pump 3/4 HP 1500 W Yes No (needs 4500 W at start) 52 min
WiFi router (adapter ceiling) up to 30 W (a rating, not a measured draw) Yes No start-up figure in the source at least 42 h 57 min
Window AC 10,000 BTU/h (ENERGY STAR derived) 667 W (sources range 540 to 729 W) Yes No start-up figure in the source 1 h 46 min to 2 h 23 min
Window AC 12,000 BTU/h (ENERGY STAR derived) 800 W (sources range 719 to 902 W) Yes No start-up figure in the source 1 h 26 min to 1 h 48 min
Window AC 15,000 BTU/h (ENERGY STAR derived) 1042 W (sources range 938 to 1042 W) Yes No start-up figure in the source 1 h 14 min to 1 h 22 min
Window AC 5,000 BTU/h (ENERGY STAR derived) 347 W (sources range 347 to 382 W) Yes No start-up figure in the source 3 h 22 min to 3 h 43 min
Window AC 8,000 BTU/h (ENERGY STAR derived) 533 W (sources range 497 to 606 W) Yes No start-up figure in the source 2 h 8 min to 2 h 36 min
Window air conditioner 12,000 BTU/h (generator tables) 1200 W (sources range 800 to 3250 W) sources disagree Only at the low end Yes (needs 3200 W at start) (low-confidence figure in its source) 24 min to 1 h 37 min (only if it draws within the continuous rating)

Laundry

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
Clothes dryer (electric) 1000 W (sources range 1000 to 4850 W) sources disagree Only at the low end No (needs 4000 W at start) (low-confidence figure in its source) 16 min to 1 h 17 min (only if it draws within the continuous rating)
Washing machine (without hot water draw) 500 W (sources range 500 to 1000 W) sources disagree Yes Yes (needs 1700 W at start) 1 h 17 min to 2 h 35 min

Electronics

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
Cell phone charger 20 W Yes No start-up figure in the source 64 h 26 min
Computer monitor ~24 in (ENERGY STAR) 12.4 W (sources range 10.3 to 14.8 W) Yes No start-up figure in the source 87 h 4 min to 125 h 6 min
Computer monitor ~27 in (ENERGY STAR) 16.7 W (sources range 12.2 to 25.2 W) Yes No start-up figure in the source 51 h 8 min to 105 h 37 min
Computer monitor ~32 in (ENERGY STAR) 27.4 W (sources range 20 to 36.2 W) Yes No start-up figure in the source 35 h 36 min to 64 h 26 min
Desktop computer 100 W (sources range 100 to 200 W) sources disagree Yes No start-up figure in the source 6 h 27 min to 12 h 53 min
Desktop computer, Apple Mac mini (M4 Pro, 2024) 5 to 140 W Yes No start-up figure in the source 9 h 12 min to 257 h 43 min
Desktop computer, Apple Mac mini (M4, 2024) 4 to 65 W Yes No start-up figure in the source 19 h 49 min to 322 h 9 min
Game console, PlayStation 5 (all SKUs) 215 W (sources range 197 to 219.2 W) Yes No start-up figure in the source 5 h 53 min to 6 h 32 min
Laptop 60 W Yes No start-up figure in the source 21 h 29 min
Radio (AM/FM) 100 W (sources range 70 to 200 W) Yes No start-up figure in the source 6 h 27 min to 18 h 25 min
Tablet charging (ENERGY STAR slate/tablet) up to 65 W (a rating, not a measured draw) Yes No start-up figure in the source at least 19 h 49 min
TV ~32 in (ENERGY STAR certified) 31.5 W (sources range 27.2 to 35.6 W) Yes No start-up figure in the source 36 h 12 min to 47 h 23 min
TV ~43 in (ENERGY STAR certified) 60 W (sources range 45.1 to 77.8 W) Yes No start-up figure in the source 16 h 34 min to 28 h 34 min
TV ~55 in (ENERGY STAR certified) 86 W (sources range 61.3 to 113.6 W) Yes No start-up figure in the source 11 h 21 min to 21 h 1 min
TV ~65 in (ENERGY STAR certified) 117.8 W (sources range 84.5 to 134.5 W) Yes No start-up figure in the source 9 h 35 min to 15 h 15 min
TV ~75 in (ENERGY STAR certified) 142.4 W (sources range 119.5 to 150.2 W) Yes No start-up figure in the source 8 h 35 min to 10 h 47 min
TV ~85 in (ENERGY STAR certified) 184.6 W (sources range 166.2 to 215.2 W) Yes No start-up figure in the source 5 h 59 min to 7 h 45 min
TV, LED (generator tables) 80 W (sources range 80 to 400 W) sources disagree Yes No start-up figure in the source 3 h 13 min to 16 h 6 min

Tools

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
Angle grinder 800 W Yes Yes (needs 3200 W at start) 1 h 37 min
Circular saw 1500 W Yes Yes (needs 3500 W at start) 52 min
Drill (corded) 600 W Yes Yes (needs 1450 W at start) 2 h 9 min
Hammer drill 1000 W Yes No (needs 4000 W at start) 1 h 17 min
Reciprocating saw 1000 W Yes No start-up figure in the source 1 h 17 min
Table saw 1800 W Yes No (needs 4300 W at start) 43 min
Work light 100 W Yes Yes (needs 2600 W at start) (low-confidence figure in its source) 12 h 53 min

Outdoor and travel

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
Electric cooler (12 V compressor cooler, generator tables) 50 W Yes No start-up figure in the source 25 h 46 min
Electric cooler, Dometic CFX3 100 73 W Yes No start-up figure in the source 17 h 39 min
Electric cooler, Dometic CFX3 35 50 W Yes No start-up figure in the source 25 h 46 min
Electric pump for inflatables 500 W Yes Yes (needs 2000 W at start) 2 h 35 min
Projector, Epson Home Cinema 2350 280 W (sources range 242 to 316 W) Yes No start-up figure in the source 4 h 5 min to 5 h 19 min

Medical devices

Appliance Draw Within continuous rating? Start-up surge OK? Runtime
CPAP machine, Philips DreamStation CPAP Pro with/without humidifier (plain wattage fact) up to 80 W (a rating, not a measured draw) Yes No start-up figure in the source at least 16 h 6 min
CPAP machine, ResMed AirSense 11 (plain wattage fact) 56.1 W (sources range 56.1 to 73.2 W) Yes No start-up figure in the source 17 h 36 min to 22 h 58 min
Portable oxygen concentrator, Inogen One G5 (plain wattage fact) up to 120 W (a rating, not a measured draw) Yes No start-up figure in the source at least 10 h 44 min

Try your own device in the runtime calculator (prefilled with the usable Wh above and 100% efficiency, so it matches the table).