EcoFlow DELTA 2
Where to buy
No store link yet.
Specifications
| Spec | Value | Source | Checked |
|---|---|---|---|
| Nominal capacity | 1024 Wh | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "Capacity 1,024Wh, 51.2V". | |||
| Usable capacity (maker's figure) | Not published by the maker | none: nothing to cite | |
| Not stated in the manual. | |||
| AC output, continuous | 1800 W | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "Pure Sine Wave, 1,800W total (surge 2,700W), 120V~ (50Hz/60Hz)". "Max X-Boost Output Power 2,200W". | |||
| AC output, surge | 2700 W | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "(surge 2,700W)". | |||
| AC outlets | 6 outlets | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "AC (x6)"; plug type not stated in the text read. | |||
| Battery chemistry | LFP | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "Cell Chemistry LFP". | |||
| Rated charge cycles | 3000 cycles to 80+% capacity | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "Cycle Life 3,000 cycles to 80% + capacity". | |||
| Max solar input | 500 W | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "Solar Charging 11-60V 15A Max, 500W Max". | |||
| Solar input voltage | 11-60 V DC | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. 15 A max. | |||
| Recharge time from AC | 100% in 72 min (condition not stated; AC X-Stream fast charging is 1,200W max) | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. Diagram caption "Fully charged in 1.2hrs", converted to 72 min. No 80% figure and no test condition printed next to the caption. | |||
| Weight | 12 kg | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "Net Weight Approximately 12 kg (27 lbs)". | |||
| Dimensions | 400 x 211 x 281 mm | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "400 x 211 x 281 mm (15.7 x 8.3 x 11.1 in)"; axis labels (L x W x H) not stated. | |||
| Warranty | Not published by the maker | none: nothing to cite | |
| Manual refers to a warranty card but prints no term. | |||
| Expandable capacity | supported extra batteries: DELTA 2 Smart Extra Battery; max extra batteries: 1; max total wh: not stated | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "A single DELTA 2 can connect up to 1 Smart Extra Battery". Extra battery capacity is in a separate manual, not read, so the total is null. | |||
| UPS switch-over time | 30 ms | source | |
| EcoFlow DELTA 2 User Manual V1.0 (EN), Specifications page. "automatically switch to the battery powered supply mode within 30ms" (EPS); the manual says it is not a 0 ms UPS. | |||
Price
We show no price here. Store prices change daily and we have no price feed yet, and the maker does not state a list price (MSRP) on the pages we read. The button above goes to the maker's page, which shows today's price.
Who it is NOT for
- No rule-based warning applies; read the table and your own power needs first.
What it can run
Usable capacity used: 870.4 Wh calculated by us from the nominal 1024 Wh x 0.85 . The maker publishes no usable figure, so we assume 85% of nominal is usable. That factor is our assumption, not a measurement of this unit.
Runtime = usable Wh / watts the appliance draws, as constant draw. Continuous check against 1800 W; start-up check against 2700 W surge . Appliance figures are from the appliance database, which shows each source; where sources disagree we show the range, not an average. 13 appliances have no usable figure yet and are left out. Runtimes calculated by us from the usable Wh above and each appliance's watts .
Kitchen
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| Air fryer (generic) | 1500 W | Yes | No start-up figure in the source | 35 min |
| Blender (generic) | 500 W | Yes | Yes (needs 1200 W at start) | 1 h 44 min |
| Chest freezer (ENERGY STAR avg, n small) | 24.3 W (24 h average) | Yes | No start-up figure in the source | 35 h 49 min |
| Coffee maker (drip) | 800 W (sources range 750 to 1200 W) sources disagree | Yes | No start-up figure in the source | 44 min to 1 h 10 min |
| Compact freezer (ENERGY STAR avg) | 27.9 W (24 h average) | Yes | No start-up figure in the source | 31 h 12 min |
| Compact refrigerator / dorm fridge (ENERGY STAR avg) | 28.1 W (24 h average) | Yes | No start-up figure in the source | 30 h 59 min |
| Dishwasher | 1200 W | Yes | Yes (needs 2700 W at start) | 44 min |
| Electric burner (single hot plate) | 1300 W (sources range 1300 to 2400 W) | Only at the low end | No (needs 4300 W at start) (low-confidence figure in its source) | 22 min to 40 min (only if it draws within the continuous rating) |
| Electric grill | 1500 W | Yes | No (needs 4500 W at start) (low-confidence figure in its source) | 35 min |
| Electric range with oven | 12200 W | No | No start-up figure in the source | not supported (above the continuous rating) |
| Electric skillet | 1000 W | Yes | No (needs 3000 W at start) (low-confidence figure in its source) | 52 min |
| Electric stove (generic, Champion) | 2000 W | No | No start-up figure in the source | not supported (above the continuous rating) |
| High-power blender (Vitamix 5200) | up to 1380 W (a rating, not a measured draw) | Yes | No start-up figure in the source | at least 38 min |
| Microwave oven | 800 W (sources range 600 to 1500 W) | Yes | No (needs 2800 W at start) (low-confidence figure in its source) | 35 min to 1 h 27 min |
| Multi-cooker / pressure cooker (Instant Pot Duo 6 qt) | 1000 W | Yes | No start-up figure in the source | 52 min |
| Refrigerator, bottom freezer (ENERGY STAR avg) | 62.9 W (24 h average) | Yes | No start-up figure in the source | 13 h 50 min |
| Refrigerator, freezerless/single door (ENERGY STAR avg) | 32.9 W (24 h average) | Yes | No start-up figure in the source | 26 h 27 min |
| Refrigerator, side-by-side (ENERGY STAR avg) | 71.2 W (24 h average) | Yes | No start-up figure in the source | 12 h 13 min |
| Refrigerator, top freezer (ENERGY STAR avg) | 41.4 W (24 h average) | Yes | No start-up figure in the source | 21 h 1 min |
| Refrigerator/freezer (full size, generic) | 700 W (sources range 400 to 750 W) sources disagree | Yes | No (needs 2900 W at start) | 1 h 10 min to 2 h 11 min |
| Toaster | 900 W (sources range 850 to 1100 W) sources disagree | Yes | No start-up figure in the source | 47 min to 1 h 1 min |
| Toaster oven | 1200 W | Yes | No start-up figure in the source | 44 min |
| Upright freezer (ENERGY STAR avg) | 50 W (24 h average) | Yes | No start-up figure in the source | 17 h 24 min |
Home
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| Ceiling fan 36-45 in (ENERGY STAR) | 22 W (sources range 3 to 35.3 W) | Yes | No start-up figure in the source | 24 h 39 min to 290 h 8 min |
| Ceiling fan 48-52 in (ENERGY STAR) | 28.6 W (sources range 3.3 to 47.2 W) | Yes | No start-up figure in the source | 18 h 26 min to 263 h 45 min |
| Ceiling fan 54-60 in (ENERGY STAR) | 32.2 W (sources range 3.2 to 41.4 W) | Yes | No start-up figure in the source | 21 h 1 min to 272 h |
| Central air conditioner 3 ton | 6000 W | No | No (needs 18000 W at start) | not supported (above the continuous rating) |
| Dehumidifier ~25 pints/day (ENERGY STAR derived) | 262 W (sources range 220 to 289 W) | Yes | No start-up figure in the source | 3 h 1 min to 3 h 57 min |
| Dehumidifier ~35 pints/day (ENERGY STAR derived) | 347 W (sources range 294 to 400 W) | Yes | No start-up figure in the source | 2 h 11 min to 2 h 58 min |
| Dehumidifier ~50 pints/day (ENERGY STAR derived) | 488 W (sources range 396 to 491 W) | Yes | No start-up figure in the source | 1 h 46 min to 2 h 12 min |
| Desk lamp | 40 W | Yes | Yes (needs 740 W at start) (low-confidence figure in its source) | 21 h 46 min |
| Electric heat pump | 6000 W | No | No (needs 18000 W at start) | not supported (above the continuous rating) |
| Electric water heater (50 gal) | 4500 W (sources range 4500 to 5000 W) | No | No start-up figure in the source | not supported (above the continuous rating) |
| Furnace blower fan 1/2 HP | 600 W | Yes | Yes (needs 1800 W at start) | 1 h 27 min |
| Furnace blower fan 1/3 HP | 450 W (sources range 450 to 700 W) sources disagree | Yes | Yes (needs 1350 W at start) | 1 h 15 min to 1 h 56 min |
| Furnace blower fan 1/4 HP | 400 W | Yes | Yes (needs 1200 W at start) | 2 h 11 min |
| Garage door opener 1/2 HP | 1050 W | Yes | No (needs 3150 W at start) | 50 min |
| Garage door opener 1/3 HP | 750 W | Yes | Yes (needs 2250 W at start) | 1 h 10 min |
| Hair dryer | 600 to 1400 W | Yes | No start-up figure in the source | 37 min to 1 h 27 min |
| Home security system | 200 W | Yes | No start-up figure in the source | 4 h 21 min |
| Household lights (per fixture, generic) | 40 to 150 W | Yes | No start-up figure in the source | 5 h 48 min to 21 h 46 min |
| Humidifier | 177 W | Yes | No start-up figure in the source | 4 h 55 min |
| Incandescent bulb 60 W | 60 W | Yes | No start-up figure in the source | 14 h 30 min |
| Incandescent bulb 75 W | 75 W | Yes | No start-up figure in the source | 11 h 36 min |
| LED bulb 15 W | 15 W | Yes | No start-up figure in the source | 58 h 2 min |
| Portable heater with fan | 500 to 1500 W | Yes | No start-up figure in the source | 35 min to 1 h 44 min |
| Room air purifier (ENERGY STAR avg) | 17.4 W (24 h average) | Yes | No start-up figure in the source | 50 h 1 min |
| Space heater (electric) | 1500 W (sources range 500 to 1500 W) sources disagree | Yes | No start-up figure in the source | 35 min to 1 h 44 min |
| Starlink Standard kit (dish + router) | 50 to 75 W | Yes | No start-up figure in the source | 11 h 36 min to 17 h 24 min |
| Sump pump 1/2 HP | 1050 W (sources range 1000 to 1050 W) sources disagree | Yes | No (needs 3250 W at start) | 50 min to 52 min |
| Sump pump 1/3 HP | 800 W | Yes | Yes (needs 2100 W at start) | 1 h 5 min |
| Vacuum cleaner | 800 W | Yes | No start-up figure in the source | 1 h 5 min |
| Well pump 1/2 HP | 1000 W | Yes | No (needs 3000 W at start) | 52 min |
| Well pump 1/3 HP | 1000 W (sources range 750 to 1000 W) sources disagree | Yes | No (needs 3000 W at start) | 52 min to 1 h 10 min |
| Well pump 3/4 HP | 1500 W | Yes | No (needs 4500 W at start) | 35 min |
| WiFi router (adapter ceiling) | up to 30 W (a rating, not a measured draw) | Yes | No start-up figure in the source | at least 29 h 1 min |
| Window AC 10,000 BTU/h (ENERGY STAR derived) | 667 W (sources range 540 to 729 W) | Yes | No start-up figure in the source | 1 h 12 min to 1 h 37 min |
| Window AC 12,000 BTU/h (ENERGY STAR derived) | 800 W (sources range 719 to 902 W) | Yes | No start-up figure in the source | 58 min to 1 h 13 min |
| Window AC 15,000 BTU/h (ENERGY STAR derived) | 1042 W (sources range 938 to 1042 W) | Yes | No start-up figure in the source | 50 min to 56 min |
| Window AC 5,000 BTU/h (ENERGY STAR derived) | 347 W (sources range 347 to 382 W) | Yes | No start-up figure in the source | 2 h 17 min to 2 h 31 min |
| Window AC 8,000 BTU/h (ENERGY STAR derived) | 533 W (sources range 497 to 606 W) | Yes | No start-up figure in the source | 1 h 26 min to 1 h 45 min |
| Window air conditioner 12,000 BTU/h (generator tables) | 1200 W (sources range 800 to 3250 W) sources disagree | Only at the low end | No (needs 3200 W at start) (low-confidence figure in its source) | 16 min to 1 h 5 min (only if it draws within the continuous rating) |
Laundry
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| Clothes dryer (electric) | 1000 W (sources range 1000 to 4850 W) sources disagree | Only at the low end | No (needs 4000 W at start) (low-confidence figure in its source) | 11 min to 52 min (only if it draws within the continuous rating) |
| Washing machine (without hot water draw) | 500 W (sources range 500 to 1000 W) sources disagree | Yes | Yes (needs 1700 W at start) | 52 min to 1 h 44 min |
Electronics
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| Cell phone charger | 20 W | Yes | No start-up figure in the source | 43 h 31 min |
| Computer monitor ~24 in (ENERGY STAR) | 12.4 W (sources range 10.3 to 14.8 W) | Yes | No start-up figure in the source | 58 h 49 min to 84 h 30 min |
| Computer monitor ~27 in (ENERGY STAR) | 16.7 W (sources range 12.2 to 25.2 W) | Yes | No start-up figure in the source | 34 h 32 min to 71 h 21 min |
| Computer monitor ~32 in (ENERGY STAR) | 27.4 W (sources range 20 to 36.2 W) | Yes | No start-up figure in the source | 24 h 3 min to 43 h 31 min |
| Desktop computer | 100 W (sources range 100 to 200 W) sources disagree | Yes | No start-up figure in the source | 4 h 21 min to 8 h 42 min |
| Desktop computer, Apple Mac mini (M4 Pro, 2024) | 5 to 140 W | Yes | No start-up figure in the source | 6 h 13 min to 174 h 5 min |
| Desktop computer, Apple Mac mini (M4, 2024) | 4 to 65 W | Yes | No start-up figure in the source | 13 h 23 min to 217 h 36 min |
| Game console, PlayStation 5 (all SKUs) | 215 W (sources range 197 to 219.2 W) | Yes | No start-up figure in the source | 3 h 58 min to 4 h 25 min |
| Laptop | 60 W | Yes | No start-up figure in the source | 14 h 30 min |
| Radio (AM/FM) | 100 W (sources range 70 to 200 W) | Yes | No start-up figure in the source | 4 h 21 min to 12 h 26 min |
| Tablet charging (ENERGY STAR slate/tablet) | up to 65 W (a rating, not a measured draw) | Yes | No start-up figure in the source | at least 13 h 23 min |
| TV ~32 in (ENERGY STAR certified) | 31.5 W (sources range 27.2 to 35.6 W) | Yes | No start-up figure in the source | 24 h 27 min to 32 h |
| TV ~43 in (ENERGY STAR certified) | 60 W (sources range 45.1 to 77.8 W) | Yes | No start-up figure in the source | 11 h 11 min to 19 h 18 min |
| TV ~55 in (ENERGY STAR certified) | 86 W (sources range 61.3 to 113.6 W) | Yes | No start-up figure in the source | 7 h 40 min to 14 h 12 min |
| TV ~65 in (ENERGY STAR certified) | 117.8 W (sources range 84.5 to 134.5 W) | Yes | No start-up figure in the source | 6 h 28 min to 10 h 18 min |
| TV ~75 in (ENERGY STAR certified) | 142.4 W (sources range 119.5 to 150.2 W) | Yes | No start-up figure in the source | 5 h 48 min to 7 h 17 min |
| TV ~85 in (ENERGY STAR certified) | 184.6 W (sources range 166.2 to 215.2 W) | Yes | No start-up figure in the source | 4 h 3 min to 5 h 14 min |
| TV, LED (generator tables) | 80 W (sources range 80 to 400 W) sources disagree | Yes | No start-up figure in the source | 2 h 11 min to 10 h 53 min |
Tools
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| Angle grinder | 800 W | Yes | No (needs 3200 W at start) | 1 h 5 min |
| Circular saw | 1500 W | Yes | No (needs 3500 W at start) | 35 min |
| Drill (corded) | 600 W | Yes | Yes (needs 1450 W at start) | 1 h 27 min |
| Hammer drill | 1000 W | Yes | No (needs 4000 W at start) | 52 min |
| Reciprocating saw | 1000 W | Yes | No start-up figure in the source | 52 min |
| Table saw | 1800 W | Yes | No (needs 4300 W at start) | 29 min |
| Work light | 100 W | Yes | Yes (needs 2600 W at start) (low-confidence figure in its source) | 8 h 42 min |
Outdoor and travel
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| Electric cooler (12 V compressor cooler, generator tables) | 50 W | Yes | No start-up figure in the source | 17 h 24 min |
| Electric cooler, Dometic CFX3 100 | 73 W | Yes | No start-up figure in the source | 11 h 55 min |
| Electric cooler, Dometic CFX3 35 | 50 W | Yes | No start-up figure in the source | 17 h 24 min |
| Electric pump for inflatables | 500 W | Yes | Yes (needs 2000 W at start) | 1 h 44 min |
| Projector, Epson Home Cinema 2350 | 280 W (sources range 242 to 316 W) | Yes | No start-up figure in the source | 2 h 45 min to 3 h 36 min |
Medical devices
| Appliance | Draw | Within continuous rating? | Start-up surge OK? | Runtime |
|---|---|---|---|---|
| CPAP machine, Philips DreamStation CPAP Pro with/without humidifier (plain wattage fact) | up to 80 W (a rating, not a measured draw) | Yes | No start-up figure in the source | at least 10 h 53 min |
| CPAP machine, ResMed AirSense 11 (plain wattage fact) | 56.1 W (sources range 56.1 to 73.2 W) | Yes | No start-up figure in the source | 11 h 53 min to 15 h 31 min |
| Portable oxygen concentrator, Inogen One G5 (plain wattage fact) | up to 120 W (a rating, not a measured draw) | Yes | No start-up figure in the source | at least 7 h 15 min |
Try your own device in the runtime calculator (prefilled with the usable Wh above and 100% efficiency, so it matches the table).